Tekmar 302P Switching Relay for 2 Zones with Priority
Tekmar 302P Switching Relay for 2 Zones with Priority
Regular price
$340.00 CAD
Regular price
Sale price
$340.00 CAD
Unit price
/
per
Ships in 1-2 days (Free Shipping)
Tekmar 302P Switching Relay for 2 Zones with Priority
This Tekmar 302P Switching Relay connects up to two thermostats and operates circulators to provide heating to a zoned hydronic heating system. Zone 1 has optional priority over zone 2 and can be used to provide heat to an indirect domestic hot water tank. The 302P includes optional exercising to prevent circulator seizure when not in use, and optional post purge operation of the last operating zone to maximize energy savings. The 302P provides a RoomResponseTM signal to modulating-condensing boilers to optimize comfort while improving boiler efficiency.
Product Features:
- CSA approved
- Unlimited zone expansion, zone priority
- RoomResponse™ signal, compatible with all low voltage thermostats
- Four ground screws, Top, bottom and back conduit knockouts
- Fuses protect transformers and pumps
- LED for each zone, priority, end switch and RoomResponse™, away signal shared between tekmar thermostats
- Pump exercising, post purge
- Two spare fuses included
- Priority override, pump exercising
- SKU: 302P
Product Specs:
- Brochure
- Brochure - Hydronic Zone Control Solutions
- Installation and Operation - 302P
- Solutions de contrôle de la zone hydronique
- Specification Sheet - 302P
- Zonage avec le signal RoomResponse
- Manufacturer Page
Agency Approvals | CSA C US |
Ambient Conditions | Indoor use only, 32 to 122 degrees F (0 to 50 degrees C), RH less than or equal to 90 percent non-condensing |
Control Load | 7 VA |
Control Type | Microprocessor control, this is not a safety (limit) control |
Dimensions | 8-3/16" H x 10-11/16" W x 2-3/8" D (208 x 271 x 60 mm) |
Enclosure Material | Cover: ABS plastic, Base: galvanized steel |
Enclosure NEMA Rating | NEMA 1 |
End Switch Relay | 24 V (ac), 5 A |
Fuses | T5A 250 V slow blow, two spare fuses included |
Mod Boiler Output1 | 0-10 V (dc) 500 ohms min load impedance |
Mod Boiler Output2 | 4-20 mA 1 k ohms max load impedance |
Power Supply | 115 V (ac) plus / minus 10 percent, 60 Hz, 11 A |
Pump Relay | 115 V (ac), 5 A, 1/3 hp, 17.3 A combined |
Transformer | 40 VA at 24 V (ac), expandable to 80 VA with additional transformer M3069 (sold separately) |
Zone Valve End Switch | 24 V (ac) |
Zone Valve Outputs | 24 V (ac) |
Zoning - Thermostat Type | Switching Relay |